#/etc/default/async

#This file contains commented-out entries for all multi-port async cards
#that have been tested at MWC, along with an explanation of how each
#board was set up, and where to get in touch with the manufacturer.
#Setups shown below are examples of actual working configurations on one
#system;  for most boards, there are many possible valid configurations.

#There are many differences among the boards.  Things to consider in
#selecting a serial board:
#-  Is the board available with 16550A-compatible (FIFO) UART parts?
#-  Are all common RS-232 circuits available for each port?  This
#   includes TD/RD/DTR/DSR/RTS/CTS/CD/RI.
#-  Is there a group status register so that individual parts do not have
#   to be polled when the board issues an interrupt?
#-  Is there provision in hardware for dealing with limitations of the
#   edge-triggered interrupt system on the AT bus?  SEALEVEL, GTEK, and
#   Comtrol offer this.
#-  Can boards be chained on the same interrupt line?
#-  What sort of cables and connectors are provided with the board?
#-  Are UART parts socketed?
#-  Is documentation intelligible and complete?
#-  Is technical support helpful, and readily available?

#The "asy" driver shipped with COHERENT 4.0 allows you to mix several
#different board types on the same system, as long as each port has its
#own channel number and the total number of channels is no more than 32.
#Each board should be configured to occupy a unique interrupt number,
#unless you are chaining boards specifically designed to allow sharing of
#an interrupt line.

#The file begins with uncommented entries for the usual com1-com4,
#occupying channels 0-3.  Unless noted otherwise, all sample multiport
#configurations are shown in addition to these ports, with additional
#channels starting at number 4.

#Record formats:
#
#P	Port	Irq	OUT[12]	Excl	Speed	Channel	Nms
#
#G	Port	Irq	OUT[12]	Type	Number-of-Slots	Nms
#
#M	Port	Speed	Slot	Channel
#
#------------------------------------------------------

# com1/2/3/4
P	3f8	4	8	1	9600	0	0
P	2f8	3	8	1	9600	1	0
P	3e8	4	8	1	9600	2	0
P	2e8	3	8	1	9600	3	0

#------------------------------------------------------
#SEALEVEL Systems, Inc.
#P.O. Box 830
#102 W. Main St.
#Liberty, SC 29657
#803-843-4343

#TURBO COMM+4  - one group of 4 ports, channels 4-7

#i/o base 0x1A0, irq 11, status at 0x1A7

#Jumper	  1111
#E1	OM5210765432
#	.X..X...
#	.X..X...

#	SW1
#	12345678
#On	XXXX..X.
#Off	....XX.X

#G	1A7	11	8	1	4	0
#M	1A0	9600	0	4
#M	1A8	9600	1	5
#M	1B0	9600	2	6
#M	1B8	9600	3	7

#TURBO COMM+8

#The configuration of the TURBO COMM+8 below shows how this board can be
#used to give three ports their own interrupt - they will be connected to
#modems, and will have heavy traffic - and put the remaining five ports
#in a single group on another interrupt line.  Port channels start at 0
#as this system is used without conventional com1-com4 equipment.

#single port at 0x280 using irq 4
#single port at 0x288 using irq 3
#single port at 0x290 using irq 10
#remaining five ports at i/o base 0x298, irq 7, status at 0x287

#Jumper	  2  3  4  5  6  7  10 11 12 15
#E1	  .  .  X  .  .  .  .  .  .  .		E10  7 .XX. .XX. 5
#E2	  .  X  .  .  .  .  .  .  .  .		     8 .XX. .XX. 6
#E3	  .  .  .  .  .  .  X  .  .  .
#E4	  .  .  .  .  .  X  .  .  .  .		E9   3 .XX. XX.. 1
#E5	  .  .  .  .  .  X  .  .  .  .		     4 XX.. XX.. 2
#E6	  .  .  .  .  .  X  .  .  .  .
#E7	  .  .  .  .  .  X  .  .  .  .		E11  PAL  SW
#E8	  .  .  .  .  .  X  .  .  .  .		     ..   XX

#	SW1
#	1234567
#On	XXX.X.X
#Off	...X.X.

#P	280	4	8	1	19200	0	0
#P	288	3	8	1	19200	1	0
#P	290	10	8	1	2400	2	0

#G	287	7	8	1	5	0
#M	298	9600	3	3
#M	2A0	9600	4	4
#M	2A8	9600	5	5
#M	2B0	9600	6	6
#M	2B8	9600	7	7

#------------------------------------------------------
#Comtrol Corporation
#2675 Patton Rd
#P.O. Box 64750
#St Paul, MN 55164
#800-926-6876
#612-631-7654 (US)
#(44) 844-261-634 (UK)

#Hostess 550 16 - two groups of 8 ports, channels 4-19

#i/o base 0x500, irq 12, interrupt mask enable off
#	   S1		   S2
#	12345678	12345678
#On	X.X.XXXX	.......X
#Off	.X.X....	XXXXXXX.

#G	507	12	8	1	8	0
#M	500	9600	0	4
#M	508	9600	1	5
#M	510	9600	2	6
#M	518	9600	3	7
#M	520	9600	4	8
#M	528	9600	5	9
#M	530	9600	6	10
#M	538	9600	7	11

#G	547	12	8	1	8	0
#M	540	9600	0	12
#M	548	9600	1	13
#M	550	9600	2	14
#M	558	9600	3	15
#M	560	9600	4	16
#M	568	9600	5	17
#M	570	9600	6	18
#M	578	9600	7	19

#------------------------------------------------------
#GTEK Inc.
#Development Hardware & Software
#P.O. Box 2310
#399 Hwy 90
#Bay St. Louis, MS 39521-2310
#601-467-8048

#PCSS-8TX

#i/o base 0x280, irq 7, status at 0x2BF

#Jumpers		JB1	JB2	JB3
#		23457
#		....X	X	.
#		....X	X	.

#G	2BF	7	8	3	8	0
#M	280	9600	0	4
#M	288	9600	1	5
#M	290	9600	2	6
#M	298	9600	3	7
#M	2A0	9600	4	8
#M	2A8	9600	5	9
#M	2B0	9600	6	10
#M	2B8	9600	7	11

#------------------------------------------------------
#DigiBoard Inc.
#6751 Oxford St.
#St. Louis Park
#MN 55426
#612-943-9020

#DigiCHANNEL PC/16 - one group of 16 ports, channels 4-19

#Below is for PAL's 40000246 and 40000247, board 0.
#Eight ports starting at 0x100, eight more starting at 0x148.
#Status at 0x142.
#Jumpers - shunt at J6 (irq 7).  J7 across pins 2&3.

#G	142	7	8	4	16	0
#M	100	9600	0	4
#M	108	9600	1	5
#M	110	9600	2	6
#M	118	9600	3	7
#M	120	9600	4	8
#M	128	9600	5	9
#M	130	9600	6	10
#M	138	9600	7	11
#M	148	9600	8	12
#M	150	9600	9	13
#M	158	9600	10	14
#M	160	9600	11	15
#M	168	9600	12	16
#M	170	9600	13	17
#M	178	9600	14	18
#M	180	9600	15	19

#------------------------------------------------------
#Arnet Corporation
#618 Grassmere Park Drive, #6
#Nashville, TN 37211
#615-834-5222

#Multiport - one group of 8 ports, channels 4-11
#UART address 0x280, option address 0x270, irq 7

#	 S1	  S2	  S3
#	12345	1234567	123456
#On	XX.X.	X...XX.	.....X
#Off	..X.X	.XXX..X	XXXXX.

#G	272	7	0	2	8	0
#M	280	9600	0	4
#M	288	9600	1	5
#M	290	9600	2	6
#M	298	9600	3	7
#M	2A0	9600	4	8
#M	2A8	9600	5	9
#M	2B0	9600	6	10
#M	2B8	9600	7	11

#------------------------------------------------------
#Applied Digital
#HCR 63
#Box 130C West Plains
#MO 65775
#417-257-1894

#SIO4

#First configuration - 4 ports starting at 0x280, using irq 7.

#	ADR Switch	Jumpers
#	12345		23457D
#On	XX.X.		....X.
#Off	..X.X

#P	280	7	8	0	9600	4	0
#P	288	7	8	0	9600	5	0
#P	290	7	8	0	9600	6	0
#P	298	7	8	0	9600	7	0

#Second configuration - this replaces the usual com1-com4.
#The advantage is that all four ports may run in interrupt mode at once.

#	ADR Switch	Jumpers
#	12345		23457D
#On	XX.X.		.....X
#Off	..X.X

#P	3f8	4	8	0	9600	0	0
#P	2f8	3	8	0	9600	1	0
#P	3e8	4	8	0	9600	2	0
#P	2e8	3	8	0	9600	3	0

#------------------------------------------------------
#Star Gate Technologies, Inc.
#29300 Aurora Rd
#Solon, OH 44139
#1-800-782-7428
#216-349-1860

#PLUS 8
#PAL 800000-01 Secondary Addresses.  Normal interrupt mode on irq 2/9.
#Eight ports starting at 0x180.

#	  SW1
#	12345678
#On	X.....X.
#Off	.XXXXX.X

#G	580	9	8	1	8	0
#M	180	9600	0	4
#M	188	9600	1	5
#M	190	9600	2	6
#M	198	9600	3	7
#M	1A0	9600	4	8
#M	1A8	9600	5	9
#M	1B0	9600	6	10
#M	1B8	9600	7	11

#------------------------------------------------------
#Connect Tech Inc
#340 Woodlawn Road West
#Unit 20
#Guelph, Ontario
#N1H 7K6
#519-836-1291

#DFlex Serial Communications Board - one group of 8 ports, channels 4-11

#i/o base 0x190, irq 10, status at 0x1D0
#	IRQ Jumpers
#	    1111
#	34570125
#B	........
#.	....X...
#A	....X...
#.
#	SW1
#	12345678
#On	......XX
#Off	XXXXXX..

#G	1D0	10	8	1	8	0
#M	190	9600	0	4
#M	198	9600	1	5
#M	1A0	9600	2	6
#M	1A8	9600	3	7
#M	1B0	9600	4	8
#M	1B8	9600	5	9
#M	1C0	9600	6	10
#M	1C8	9600	7	11

#------------------------------------------------------
#Boca Research, Inc.
#6413 Congress Avenue
#Boca Raton, FL 33487
#407-997-6227

#Bocaboard BB1008
#Eight ports starting at 0x100, status register at 0x107, irq 15.

#		0000 XXXX
#		0123 XXXX	Irq
#		XXXX 046C
#Jumpers	XXXX 0000	3  4  5  7 10 11 12 15
#Set		.X.. X...	.  .  .  .  .  .  .  X

#G	107	15	8	1	8	0
#M	100	9600	0	4
#M	108	9600	1	5
#M	110	9600	2	6
#M	118	9600	3	7
#M	120	9600	4	8
#M	128	9600	5	9
#M	130	9600	6	10
#M	138	9600	7	11

# end of /etc/default/async