@Article{Davis:1991:DVV,
  author =       "Scott H. Davis",
  title =        "Design of {VMS Volume Shadowing Phase II} ---
                 Host-based Shadowing",
  journal =      j-DEC-TECH-J,
  volume =       "3",
  number =       "3",
  pages =        "7--15",
  month =        "Summer",
  year =         "1991",
  CODEN =        "DTJOEL",
  ISSN =         "0898-901X",
  bibdate =      "Thu Mar 20 18:15:43 MST 1997",
  bibsource =    "http://www.math.utah.edu/pub/tex/bib/dectechj.bib",
  URL =          "ftp://ftp.digital.com/pub/Digital/info/DTJ/v3n3/Design_of_VMS_Volume_Shadowin_01apr1992DTJ301P8.ps;
                 http://www.digital.com:80/info/DTJ301/DTJ301SC.TXT",
  abstract =     "VMS Volume Shadowing Phase II is a fully distributed,
                 clusterwide data availability product designed to
                 replace the obsolete controller-based shadowing
                 implementation. Phase II is intended to service current
                 and future generations of storage architectures. In
                 these architectures, there is no intelligent, multiunit
                 controller that functions as a centralized gateway to
                 the multiple drives in the shadow set. The new software
                 makes many additional topologies suitable for
                 shadowing, including DSSI drives, DSA drives, and
                 shadowing across VMS MSCP servers. This last
                 configuration allows shadow set members to be separated
                 by any supported cluster interconnect, including FDDI.
                 All essential shadowing functions are performed within
                 the VMS operating system. New MSCP controllers and
                 drives can optionally implement a set of shadowing
                 performance assists, which Digital intends to support
                 in a future release of the shadowing product.",
  acknowledgement = ack-nhfb,
  classcodes =   "C6150J (Operating systems); C6120 (File organisation);
                 C5310 (Storage system design)",
  classification = "C5310 (Storage system design); C6120 (File
                 organisation); C6150J (Operating systems)",
  keywords =     "availability; cluster; Cluster interconnect; data;
                 Data availability; data security; Data security; DEC
                 computers; Digital; drives; DSA; DSA drives; DSSI
                 drives; FDDI; interconnect; MSCP controllers; Operating
                 system; operating system; operating systems
                 (computers); security of; Shadow set members; shadow
                 set members; Storage architectures; storage
                 architectures; storage management; VMS MSCP servers;
                 VMS Volume Shadowing Phase II",
  thesaurus =    "DEC computers; Operating systems [computers]; Security
                 of data; Storage management",
  treatment =    "P Practical; R Product Review",
}